High Frequency Uras Vibrator

Vibrators High Frequency Vibrator High Frequency Uras Vibrator

01KHE-1-2

High Frequency Vibrators provide vibration frequencies ranging from 100 to 180Hz, which is particularly useful for concrete filling.

Developed for use in production of precast concrete, "The High Frequency Uras Vibrator" produces vibrations in the range of 100 to 180Hz. Concrete is strengthened through the use of high-frequency vibration during hardening. This technique can be applied to concrete casts of all types and sizes, for example tunnel shields or U-shapped gutters.

* A frequency drive is required to operate the High-Frequency Uras Vibrator.


Details about this product

Advantages

  • Produces vibrations in the range of 100 to 180Hz for the strengthening of precast concrete.
  • Innovative anti-vibration construction allows for easy maintenance and provides a long service life without the need for periodic greasing.
  • Compact design supports horizontal, diagonal, and vertical installation.

Primary Applications

Used as a source of vibration for applications such as filling concrete and block molding.

Primary Users

Ceramics, Chemical

Standard Specifications

Spec KHE series KHE-T series
2 Pole 2 Pole
Power Supply Three-phase 200/200V 100/120Hz Three-phase 200/200V 150/180Hz
Time Rating Continuous Rating
Thermal Class Class E Insulation
External Cover Structure
(Vibrational Force kN)
Totally-Enclosed
(IP66)
1-7.5 1-7.5
Enclosed Fan-Cooled
(IP55)
12-22 12
Power Output (kW) 0.075-2.2 0.075-1.2
Rotational Speed (r/min)
50/60Hz
6000/7200 9000/10800
Vibrational Force (kN) 1-22 1-12
Bearing
(Vibrational Force kN)
Sealed ZZ Ball 1-4 1-4
NJ Roller 7.5-22 7.5-12
Cable Enclosed Cable2PNCT (4 Core) x 2m(0.75mm2/1.25mm2)
Installation Method Attach by frame legs (any orientation is permitted).
When installing vertically or diagonally, ensure that the side with the terminal box is the higher side.
Coating Color Munsell 2.5PB5/2
Installation and Operating Environment Can be used indoors and outdoors.
Ambient Temperature (including installation base): -15°C to +40°C
Altitude: 1,000m max.Relative Humidity: 85% max with no condensation
Can be used in tropical climates.
High Frequency Uras Vibrator KHE 2 Pole
Model Max. Vibrational Force (kN) Power Output (kW)
KHE-1-2 1 0.075
KHE-2-2 2 0.15
KHE-4-2 4 0.4
KHE-7.5-2 7.5 0.75
KHE-12-2 12 1.2
KHE-16-2 16 1.6
KHE-22-2 22 2.2
High Frequency Uras Vibrator KHE-T 2 Pole
Model Max. Vibrational Force (kN) Power Output (kW)
KHE-1-2T 1 0.075
KHE-2-2T 2 0.15
KHE-4-2T 4 0.4
KHE-7.5-2T 7.5 0.75
KHE-12-2T 12 1.2
Manufacturing Range
Model Poles Models Vibrational Force (kN) Voltage Class (V) Rotational Speed (r/min) Power Output (kW)
High Frequency Type KHE 2 7 1-22 200/400 class 6000/7200 0.075-2.2
KHE-T 2 5 1-12 200/400 class 9000/10800 0.075-1.2

A wide range of voltages other than those listed above are available.
Custom design/specifications are available. Please consult with the Overseas Sales Department.




Make an inquiry about this product

For details about this product, please contact the Overseas Sales Department directly by e-mail utc_overseas@uras-techno.co.jp or our contact form.

Contact Us